Ulster Hospital Endoscopy Clinic

01/01/1970

 Extraspace Solutions designed a 10m x 4m steel framed unit located on a specially designed steel supporting framework - this enabled the building to be located at first-floor level. The building was lifted over an existing permanent building with a 200T crane and into a 5m-wide area outside the existing clinic. The new facility creates a flow of equipment from dirty through to clean and into reuse again. The building was finished with whiterock wall cladding, whiterock suspended ceiling, slip resistant floor covering, laminated door sets and full M&E installation which included linking up all new services into the existing hospital. The internal ceiling height was 2.7m, with a further 400mm void for all mechanical ventilation which was connected back to an air handling unit located on the building's roof. The Extraspace team designed a load-bearing steel framework for the unit and also fitted guard rails and access ladders. We manufactured and installed the building within 10 working weeks from date of order.