NICKEL RELEASE REGULATIONS, EN 1811:2011 - WHAT'S NEW?
EN 1811 is the internationally recognised test method which was devised almost 12 years ago to determine the rate of nickel release from jewellery, spectacle frames and other items. The test was devised to assess whether articles comply with the requirements of the EU Nickel Directive which restricts the release rate of nickel from articles intended to come into direct and prolonged contact with the skin and with post assemblies intended to be inserted into piercings in the body. Sensitisation to nickel can result in severe allergic reactions. The objective of the Nickel Directive is to reduce the incidence of nickel dermatitis by preventing non-compliant items from reaching the marketplace. The EU Nickel Directive was originally introduced in 1994, became enforceable in 2000 and was amended and updated in 2005. The 2005 requirements were subsequently amalgamated into the REACH regulation [Ref: REGULATION (EC) No 1907/2006, Entry 27 of Annexe 17 (REACH)]. REACH is a European Union regulation concerning the Registration, Evaluation, Authorisation and restriction of CHemicals. It came into force on 1st June 2007 and replaced a number of European Directives and Regulations with a single system. The Annex XVII of REGULATION (EC) No 1907/2006, came into force from 1 June 2009) Under the legislation any manufacturer, importer, wholesaler or retailer in the supply chain will commit an offence if: · They sell a post assembly intended to be inserted into a pierced part of the human body unless the rate of nickel release from the post assembly is less than 0.2 μg/cm2/week; · They sell jewellery items, including certain metal clothing fasteners, if the rate of nickel release from those parts of the product which come into direct and prolonged contact with the skin is greater than 0.5 μg/cm2/week. · They sell any jewellery items, including certain metal clothing fasteners, where these have a non-nickel coating unless the coating is sufficient to ensure that the rate of nickel release from those parts of the product which come into direct and prolonged contact with the skin does not exceed 0.5 μg/cm2/week for a period of at least two years normal use of the product. Changes to En 1811:1998 There are many factors which can affect the level and rate of nickel release from a nickel alloy. Apart from the actual nickel content and composition of the alloy these include surface finish, non-homogeneity, and plating among others. As a consequence, results from testing according to the EN 1811:1998 + A1:2008 standard test method have sometimes been shown to be subject to variability and uncertainty. This is acknowledged by the fact that the EN 1811:1998 method requires that the test result be multiplied by a correction factor of 0.1 in order to compensate for these variables and try to obtain a more consistent and comparable nickel release figure. Effectively this means that an article recording an actual release rate of as much as 5.0µg/cm²/week or 2.0µg/cm²/week, depending upon type of article, when tested by EN 1811:1998 would still be deemed to be compliant to the Directive once the correction factor of 0.1 had been applied In 2010, the EU granted a mandate to CEN TC 347 TG 1 (the European Committee tasked with revision of the international standard) to examine the EN 1811:1998 test procedure and the related uncertainties. In order to protect the health of the consumer it wanted to develop and introduce a more reliable / robust procedure, remove or reduce the adjustment factor of 0.1 and deliver a test method which was more accurate and reproducible. Following the work undertaken by the CEN Committee the 1998 standard has now been superseded and replaced with EN 1811:2011. Summary of Differences between the 1998 and the 2011 standard: The main difference between the 1998 and the 2011 standard is that the existing correction factor of 0.1 has been replaced by an uncertainty of measurement (ut,r = 46 %, ut,r is related to the relative reproducibility). This has the effect of effectively lowering the compliance limit for nickel release, so products which were currently compliant with the regulations may cease to be when tested to the revised standard. The new standard also features a 'no decision' category of result due to the move away from the use of a correction factor and adoption of an uncertainty of measurement approach to assessing test results. 'No decision' captures the range of results where, after testing to the revised standard, no clear decision is possible, due to interpretation of the measurement of uncertainty of results. A "No decision" verdict does not mean that the article is not compliant; but